If this problem persists, try reloading the page. Furnace not working? Rheem - Your product is defective, not assembled prior to being boxed for shipment. If you have problems accessing your account, please contact us at 1-888-757-4774 and we'll help you out. I have a Rheem heater with a control board with a part number of 62-25338-01 and I get a blink code of 3 flashes and I All Rheem Circuit Boards and Control Boards are brand new in the original factory packaging and are guaranteed to fit and function properly. PROTECH 47-102077-05 - Control Board. Integrated Controls board features dip switches for easy system set up; QR code for quick access to product information from your smart phone or tablet; Some DIY installers hook up the remote control wires to the 2 screws on the lower left of the control board inside the unit. In Stock. Best of luck. If this problem persists, try reloading the page. Compare Now Compare Now. Do you suspect that your furnace/AC control board is bad? $127.95. $232.11. I am most interested in the function of the Y1 terminal on the board. Get genuine Rheem factory OEM Circuit Boards and Control Boards for your Rheem HVAC unit. All Rheem Circuit Boards and Control Boards are brand new in the original factory packaging and are guaranteed to fit and function properly. We have fast FREE SHIPPING on all orders over $99 and ship all orders within 1 business day. The unit has developed a leak and finally lost eneough to trip the switch. If you are still under warranty, Contact Us. Dirty fuse (also, do make sure that the fuse is not too small for your furnace) Loose wiring (the wires might become loose over time due to vibration) Read: Why Does Home Thermostat Say HEAT ON But There Is No Heat? The circuit or control board can fail for quite a few reasons. We have fast FREE SHIPPING on all orders over $99 and ship all orders within 1 business day. Ruud and Rheem energize the reversing valve in the heating mode. FREE Shipping by Amazon. Quality Rheem Circuit Board & Timer Parts From Repair Clinic. This video provides step-by-step instructions for replacing the control board on Rheem furnaces. Home; Product Categories; Water Heater Control Boards; Water Heater Control Boards Showing 1 - 12 (of 12) results. NPT input, 3/4 in. Part # SP20303B. 1308 Electric Heating Element Failures 1308 Technical Bulletin the control will almost immediately drop out and unit goes into retrial and possibly soft and hard lockouts modes. This recall involves Rheem branded Performance Platinum electric water heaters in 40, 50 and 80 gallon capacities, and they were sold exclusively at The Home Depot stores nationwide and online from January 2014 through April 2016. The majority of Rheem air conditioners are affordable and, on average, get high customer ratings, so no wonder a lot of homeowners choose to go for a cooling. Here you can find replacement Circuit Boards and Control Boards for Rheem Water Heaters. Clean the Intake. I took the panel off & followed - Answered by a verified HVAC Technician. What it is: the main control board is the part of the system that provides voltage to the whole unit. Quantity Add To Cart. Watch Video. Overblowing: If your furnace is blowing too much air, then it could be an issue with the control board or a problem with the thermostat. I am going to remove the board, put it on the bench with an appliance cord plugged into a known good grounded circuit. ECONET DEFROST CONTROL BOARD 2 STAGE. Technical Details. If you have problems accessing your account, please contact us at 1-888-757-4774 and we'll help you out. Rheem Outside Unit not Coming On Is your outside unit not running? This could be issued with the circuit breaker, which is generally caused by a power surge, hence powering your AC system. We carry more than 4 million parts from over 175 major brands, so chances are, we've got the part you need. START A LIVE CHAT. Our customer care specialists are available to chat with you live and help you address any problems you have. In this video we talk about the problem Rheem is having with there defrost control boards and sensors. 27% Off MSRP: $316.44. Rheem Control Board. SHOP FOR PARTS. I'm sorry, your email address was not found in our system. Rheem Air Handler Fan Problems If you realize your air conditioners blower fan is not working, this could be an issue with a defective thermostat, banned out blower motor, bad control board, or a spoilt selector switch. Contact an HVAC technician to help you fix any issue causing your air conditioners fan to have problems. we have just received the 2nd defective (with this one being 100% totally unassembled) water softener. IN STOCK. Steve. You will get no power to your main remote control if you attach the 2 wires of your main remote control incorrectly. May 24, 2021. It is after the wires from the transformer and is covered in a rubber holder and is about 1 inch long. the filter is plugged, blower motor bad etcsomething that greatly dimishes air flow. RGPS - 07EAMER . Order Rheem control boards today with fast shipping and easy returns. 2. This control board is in Rheem RH1T4821STANJ air handlers. Four tabs hold each corner of the board to the lid. If the potential is not right, then -- bad board. $66.50 $ 66. The model number and name for the following item is: Rheem 62-24084-82 Control Board. Quick View. Rheem 46-24124-06 - Transformer 40 VA. $36.56. 3. Dirty or clogged filter- The Rheem unit could be experiencing clogged filters that hinder airflow into the AC, thus reducing the air conditioners cooling capacity. 2 - lack of air flow. SKU: SP20260T Rheem. It is a inline fuse and you have to hunt for it. Initially, the problem was not fixed, so I called the seller. 50. Those are the 2 scenarios that trip a low pressure switch. Defective control board Check control board diagnostic codes. Locate the control board on the underside of the cover. Ships from and sold by North America HVAC. Control Board - EcoNet. HE80-200 SP20260T GHE Display And Control Board Kit - HE80-200. Remove the top cover by unhooking the two clips in the back, holding the cover onto the tank below. Most of the problems with a Rheem gas water heater will be related to the FVIR lockout. Get it Aug 22 - 25. Ships from and sold by TopDimensionSupply. The CEO must be made abreast of the issues going on with his assembly departments. Only 4 left in stock - order soon. Reload Control Board - Variable Speed. $431.79. 1207 How to Read Rheem/Ruud Serial Numbers How to Read Rheem/Ruud Serial Numbers Troubleshooting table to help diagnose problems and complaints. Rheem may have had a fuse on that board, a small glass one if you look very carefully OR they have a inline one. shane. Dirty coils- A dirty condenser coil will always cause your AC system to have trouble blowing in cold air. Shop Rheem furnace control boards and circuit boards, available in a range of prices. Gas Valve - 3/4 in. Output. Hooking up the 2 remote control wires wrongly is the main culprit behind this issue. Rheem Manufacturing Company has issued a voluntary recall on certain electric water heaters, due to a potential fire risk. All Brands > Rheem > Checkins > Repair. the wrong one Ruud heat pump trouble I put the new defrost board in because this is the problem I was already having and unit acts the same with the new board as it April 19th, 2019 - 62 24268 03 INTERGRATED HSI CONTROL BOARD Rheem Ruud FURNACE PROTECH 69 95 Item is used Conditioned USED because It is What Are the Codes for the Lights on a Rheem Furnace? Thermostat wires, control wires, gas valve, etc. 62-24268-02 - Rheem OEM Replacement Furnace Control Board. This item: Protech Rheem 62-104058-02 Integrated Furnace Control Board 1194-200. If the sensor circuit shows the right potential, then the furnace has to be the problem. Furnace or AC control board troubleshooting. The next step should be to clean the intake of the water heater. Part # 47-105395-02. No problems untill it will not start. Genuine OEM Part # 62-24140-04 | RC Item # 2638587. With most models your first step should be to press the TCO thermal reset button which is located on the front of the combustion door. Clogged filters. OEM Upgraded Rheem Heat Pump Defrost Control Circuit Board & Sensor 47-21517-16. Only 12 left in stock - order soon. Arklaflo Plumbing checked the hot water heater and after replacing the thermocouple, and checking for other problems, they stated that the gas control valve and the burner assembly needed to be replaced. I called the Rheem 800 number and they agreed to send the control valve but refused to send the burner assembly. 4.6 out of 5 stars 72. Some features have failed to load due to an internet connectivity problem. Compare Now. I would think that you have a control board problem because it sounds like the control board is sending voltage that is too high for the gas valve and it burning the gas valve coil up. My heater isnt working. The installation manual includes a sequence of operation that does not describe the operation of the control board. There will be no load whatsoever. Showing 1 - 12 of 47 Filters (0) Sort Products By 1 - lack of refrigerant. Otherwise, replacement parts can be purchased here . SKU: SP20260T. Product information . Leaking: High-efficiency furnaces certification program to find a local company that will have the skills and knowledge to address and fix any furnace problems you may be experiencing. Part # SP21181C. Get it as soon as Tue, Aug 23. A Problem with the Main Control Board. I hope you can easily find and fix the problem.